Slide background Hydroflux Pacific specialises in the design and construction of industrial wastewater treatment plants
Click through to learn more about what we do and how we can assist your needs.
Slide background With many installations of the Hydroflux ROADTRAIN packaged sewage treatment plants currently operating in resorts and camps in the Pacific Islands and worldwide, Click through to see how we can assist you.
Slide background The HyDAF Dissolved Air Flotation (DAF) - Simplicity and Exceptional Performance
Click through to learn why the HyDAF is the Dissolved Air Flotation system of choice for industrial wastewater treatment today
Slide background Proudly Delivering Mining & Wastewater Clarifiers For Over 50 Years
Click through to learn about EPCO's range of clarifiers for mining processes and industrial wastewater.
Slide background Hydroflux Pacfic can supply a comprehensive range of chemicals for wastewater treatment processes
Click through to learn more about our chemical range
Slide background Proudly Delivering Mining & Wastewater Clarifiers For Over 50 Years
Click through to learn about EPCO's range of clarifiers for mining processes and industrial wastewater.

LanceMix® Sludge Mixing Systems

The LanceMix® system has been designed to effect the homogeneous mixing of the sludge within the digester to ensure uniform temperature throughout the sludge and also to prevent the formation of a surface scum layer.

LanceMix STP Digestor Mixing System Hydroflux Epco Australia Secondary

Bio gas is drawn from the gasholder cover by the gas compressors. After the bio gas is pressurised by the compressors it is returned to the digester for injection into the sludge at depth, via one of the stainless steel lances. Five lances are fitted, but only one lance works at any time. The lances work in a sequence and for the time set in the plant control system.

Each lance is fitted with its own pneumatically actuated, anti static, fire safe ball valve. Each actuator is fitted with open and close limit switches. When a lance operating sequence change is signalled, a new lance valve must be proved open by its limit switch before the old lance valve is permitted to close. Valve closure must also be proved or a fault is indicated.

The bio gas compressors will shut down in the event of the following faults :
    •   Low bio gas delivery side flow rate
    •   Low compressor seal water flow rate
Bird In Hand STP Digestion Equipment Hydroflux Epco, Australia

Hydroflux Epco Digestion Equipment, Bird In Hand STP, Australia

Hydroflux Epco Digestion Equipment, Cessnock STP, Australia

Hydroflux Epco Digestion Equipment, Cessnock STP, Australia

Hydroflux EPCO Digestion Equipment, Liverpool STP, Australia

Hydroflux Epco Digestion Equipment, Liverpool STP, Australia

Hydroflux Epco BioCap Anaerobic Digester STP Wastewater Brochure

Hydroflux Epco BioCap® Digester Roof Systems Brochure

As a pioneer in Australia, Hydroflux Epco continues to offer EPCO Australia’s complete design, build, install and refurbishment service. Our commitment to our clients does not end with the delivery of the project and we support our clients so that that their plants continue to operate at their full design capacity well into the future.

industrybase